HomeIndustriesProductsServicesPartnersAbout Us

Customer Login

Home arrow CFD Paper Library arrow Software Tool arrow CFD-ACE arrow Effects of microreactorwall heat conduction on the reforming process ofmethane
Effects of microreactorwall heat conduction on the reforming process ofmethane
AT A GLANCE
Software Tool
Physics Used
Industry Area
Request Paper
Authors
Michael J. Stutz and Dimos Poulikakos ETH Zurich
Abstract
In this paper, the effect of wall conduction of an autothermal tubular methane microreformer is investigated numerically. It is found that the axial wall conduction can strongly influence the performance of the microreactor and should not be neglected without a careful a priori investigation ofits impact. By increasing the wall thermal conductivity, the maximum wall surface temperature is decreased. Due to the complex exothermic–endothermic nature ofthe chemistry ofref orming, the axial variation ofthe wall temperature is not monotonic. Methane conversion and hydrogen yield are strongly dependent on the wall inner surface temperature, hence the heat conduction through the channel wall. The equivalence ratio and the wall thickness also significantly affect the reforming effectiveness and must be carefully considered in reactor optimization. Furthermore, it is found that exothermic oxidation reaction mechanisms, especially partial oxidation, are responsible for syngas (hydrogen and carbon monoxide) production near the inlet. Farther downstream, in the oxygen deficient region, endothermic steam reforming is the main hydrogen producing mechanism. By increasing the thermal conductivity, steam reforming becomes stronger and partial oxidation becomes weaker. For all investigated inlet conditions, the highest hydrogen yield is obtained for no or very low conductive walls.
Keywords
Microreactor; Wall thermal conductivity; Heat transfer; Syngas; Partial oxidation; Steam reforming; Methane reforming; Fuel cells; Heat conduction; Computational chemistry
Source
Chemical Engineering Science 60 (2005) 6983 – 6997
Reviews